• Giga@hdv-tech.com
  • 24H Online Service:
    • 7189078c
    • sns03
    • 6660e33e
    • youtube 拷贝
    • instagram

    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV

    Short Description:


    Product Detail

    Product Tags

    Related Video

    Feedback (2)

    Well-run products, skilled income group, and better after-sales products and services; We have been also a unified massive family, all people stick with the business price "unification, dedication, tolerance" for Cisco Transceiver, Sfp Fiber Optic Transceiver, Zte Epon Onu, "Making the Products of High Quality" is the eternal goal of our company. We make unremitting efforts to realize the goal of "We Will Always Keep in Pace with the Time".
    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV Detail:

    额温枪IR 详情01

    额温枪IR 详情02

    额温枪IR 详情03

    额温枪IR 详情04

    额温枪IR 详情05

    1.Description

    Non-contact Body Infrared Thermometer is Specially designed fo take the body temperature of a person regardless of room temperature
    Depending on various skin types and thickness, there may be temperature difference When the indoor temperature is significant difference, the body infrared thermometer should be placed in that room for 15 to 20 minutes before using.

    2.Safety Information
    •This device must only be used for the purposes described in this instruction manual.
    •This device must only be used in an ambient temperature range between 10°C and 40°C.
    •Do not expose this thermometer to extreme temperature conditions of>40 C or<0 C.
    •Do not expose this thermometer to electric shocks
    •Do not use the device in relative humidity higher than 85%RH
    •Do not use the device near large electromagnetic fields such as found with cordless or cell phones.
    •Keep the device away from water and heat, including direct sunlight
    •Do not drop or knock the device, and dot not use if damaged
    •It may affect the accuracy of measurements when the forehead is covered by hair perspiration, cap or scarf
    •Keep the measuring distance as <5cm(<2in)
    •When the body infrared thermometer should be left in that room during 15to 20 minutes before using.
    •It may affect the accuracy of measurements when the forehead is covered by perspiration
    or other factors, please take the temperature behind the ear lobe.
    •Clean the glass with cotton bud lightly moistened with 70% alcohol

    3.Features
    •Precise non-contact measurements
    •Built-in laser pointer
    •User selectable °C or °F(Th rough the” MO DE” key long press mroe than 5 sec)
    •Automatic selection range and Display Resolution 0.1°C(32.1°F)
    •Autondsomatic Data Hold & Auto Power off
    •Set Alarm value(the alarm threshold default value is 38°C(100.°F)
    Instruction: turn on unit and pressnMODEHbutton 3 seconds, LCD display”Fl
    Re-press”MODE”to enter 38°C(dufaIt alarm setting), increase or decrease value
    By press up ordown arrow, press measurement rigger to finish setting.
    •Selection for buzze
    Instruction: turn on the unit and press”MODE”button 3 seconds, LCD display”F3
    Re-press” MODEHfor setting, press up ordown arrow for selection,,ON”or,,OFF”mode. press measurement rigger to finish setting
    •Selection for body or ambient temperature
    Operation Way: In Standby, Press the” Mode button, then the LCD screen showing”Fl 38.0°C,r, by pressing the” <to>”to change the Data, Enter into F2 setting by press MODE”one more time, then the LCD screen showing”F2 0.0°C”, you can press,toA” to change the Data, It is the same operation way for F3 and F4 Note: “5URF”For showing the object, “Body for the human being’s brow mode under the F4 setting

    4.Intended Use
    •The Non-contact Body Infrared Thermometer is designed for body surface and forehead temperature measurement for infants and adults without contacting to human body. It can be used by consumers in household environment in accordance with the ASTM 1965-1988
    •Standard specification for Infrared Thermometers for Intermittent Determination of Patient Temperature

    5.Precaution Before Use
    •In order to obtain reliable and stable results, when changing the environment to a room with a significant temperature difference, it is recommended to leave the Non-contact Boy Infrared Thermometer to this ambient temperature for 15 to 20 minutes before using it
    •Depending on various skin types and thickness, there may be temperature difference.
    •Do not expose the thermometer to sunlight or to water.
    Allow one minute interval between two measurement.

    Normal Temperatures According To Measurement Method

    Measurement

    Methodnormal Temp °C

    Normal Temp°F

    Rectal

    36.6 to 38

    97.8 to 100.4

    Oral

    35.5 to 37.5

    95.9 to 99.5

    Auxiliary

    34.7 to 37.3

    94.4 to 99.1

    Auriclar

    35.8 to 38

    96.4 to 100.4

    Temporal(Thermo Flash)

    35.8 to 37.8

    96.4 to 100.0

    The temperature of the human body varies throughout the day. It can also be influenced by numerous external factors: age, sex, type and thickness of skin
    Age

    Temp °C

    Temp°F

    0-2 years 34.6 to 38 97.8 to 100.4
    3-10 years

    36.1 to 37.8

    97.0 to 100.0
    11-65 years

    35.9 to 37.6

    96.6 to 99.7
    >65 years

    35.8 to 37.5

    96.4 to 99.5
    6.Configuration
    IRSensor
    LCD Display
    Back Light/Button
    Up Button
    Down Button
    Mode(°F°C) Button
    Measurement Switch
    Battery Cover
    Handle

    7. Technical Specifications

    Normal Conditions of Use:

    Display Resolution 0.1oC(32.1oF)
    Operating Temperature 10to40°C(50tol04.°F)
    Humidity Rate ≤85%
    Power R03AAA1.5V2
    Size 95×42.5xl56mm(LXWXH)
    Weight 124g

    Measuring Range:

    Body Measuring Range

    32.0to43.0°C(90tol09.4°F)

    Ambient Measuring Range Oto 60°C(32tol40°F)
    Body Accuracy ±0.3°C(32.54°F)
    Ambient Accuracy ±1°C(33.8°F)
    Measuring Distance

    <5cm (2 in)

    Automatic Stop

    7 sec

     Non-contact Body Infrared Thermometer Precision:

    32to35.9°C/93.2to96.6°F ±0.3°C/32.9°F According to ASTMStandard E1965-1998(2003)
    36to 39°C/96.8to 102.2°F ±0.2°C/32.36°F
    39 to 42.5/102.2 to 108.5°F ±0.3°C/32.9°F
    8.Advice
    The protective glass over the lens is the most important and fragile part of the thermometer, please take great care of it.
    Clean the glass with cotton fabric, wet with water or 70C alcohol
    Do not use other batteries than mentioned batteries, do not recharge non rechargeable batteries Do not expose the thermometer to sunlight or water.
    9.Advice For Use:
    For stable and reliable results, it is essential to check the Non-contact Body IR thermometer and change as needed, as follows:
    1st step: take the temperature of a person using a conventional thermometer; you wiU get 37.5°C(99.5°F) for instance
    2rt step: take the temperature of the same person using the Non-contact Body IR thermometer keeping the 5 cm(2 in)distance between the thermometer and the forehead (Take care to remove any obstacle which could alter the measurement(hair, perspiration.), If you get 37.5°C(99.5OF) the Non-contact Body IR thermometer is properly set and ready for use.
    Ifyou get a lower temperature, 36.4OC(97.4°F ),for example, your difference is 1.1C(33.98°F) You should adjust the temperature on the Non-contact Body R thermometer and add the difference, l.e. 1.1 C(33.98°F) Instruction: turn on unit and press”MODE”button for 3 seconds to enter”Fl”, access”F2″ by choosing up or down arrow Re-press”MODE”to acess 0.0. Increase or decrease value by press up ordown arrow, press measurement rigger to finish setting.
    3s1 step: To check, take the temperature again using the Non-contact Body IR thermometer.
    lian1EXHIBITIONSFAQ

    Product detail pictures:

    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV detail pictures

    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV detail pictures

    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV detail pictures

    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV detail pictures

    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV detail pictures

    Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV detail pictures


    Related Product Guide:
    Nokia enhances FTTH systems for 5G mobile network support | Sfp Gpon Onu
    Inphi offers 100G PAM4 QSFP28 for 80-km data center interconnect | Module Sfp

    We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Thermometer Forehead Digital - In Stock CE FDA Approved No Contact Dc 3V Digital Head Touchless Thermometer Forehead – HDV , The product will supply to all over the world, such as: Bolivia, Swedish, Johor, We'll initiate the second phase of our development strategy. Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. If you are interested in any of our products and solutions or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future.
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Lesley from Belgium - 2015.09.12 17:18
    A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Moira from Oslo - 2015.05.22 12:13
    Write your message here and send it to us
    web聊天